6.3.2 Creating a RAID 1 set (Mirror)

To create a RAID 1 set:

1.From the utility main menu, select 1. Create RAID Volume, then press <Enter>. This screen appears.

Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ESB2 wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ CREATE ARRAY MENU ]

Name:

Volume1

RAID Level:

RAID1(Mirror)

Disks:

Select Disks

Strip Size:

N/A

 

Capacity:

0.0

GB

Create Volume

[ DISK/VOLUME INFORMATION ]

Enter a string between 1 and 16 characters in length that can be used

to uniquely identify the RAID volume. This name is case sensitive and cannot

contain special characters.

[↑↓]-Select

[ESC]-Exit

[ENTER]-Select Menu

2.Enter a name for the RAID 1 set, then press <Enter>.

3.Highlight RAID Level, press the up/down arrow key to select RAID 1 (Mirror), then press <Enter>.

4.Follow steps 4 to 5 and 7 to 9 of the previous section to create the RAID 1 set.

6-34

Chapter 6: RAID configuration