ACS-1208AL / ACS-1216AL User Manual

Clear Login Information

If you are unable to perform an Administrator login (because the Username and Password information has become corrupted, or you have forgotten it, for example), you can clear the login information with the following procedure:

1.Power off the switch and remove the top cover of the Switch module case.

2.Short the jumper labeled Default Password at the right front of the switch’s main board.

3.Power on the switch.

When you power the switch on, the following message appears on the LCD display:

USERNAME AND PASSWORD INFORMATION HAS BEEN

CLEARED. PLEASE POWER OFF THE SWITCH, REMOVE

THE JUMPER, CLOSE THE CASE, THEN RESTART.

4.After you start back up, the OSD login function acts exactly the way it did the first time the switch was run (see p. 4-2) and you can reset passwords for the Administrators and Users.

A-4

2003-01-27

Page 60
Image 60
ATEN Technology ACS-1208AL, ACS-1216AL user manual Clear Login Information