F3 SET:
This function allows the Administrator and each User to set up his own working environment. A separate profile for each is stored by the OSD and is activated according to the Username that was provided during Login.
To change a setting:
1.Double Click it; or move the highlight bar to it, then press [Enter].
2.After you select an item, a submenu with further choices appears. To make a selection, either Double Click it; or move the Highlight Bar to it, then press [Enter]. An icon appears before the selected choice to indicate which one it is. The settings are explained in the following table:
Setting | Function |
OSD HOTKEY | Selects which Hotkey activates the OSD function: |
| [Scroll Lock] [Scroll Lock] or [Ctrl] [Ctrl]. |
| Since the Ctrl key combination may conflict with programs |
| running on the computers, the default is the Scroll Lock |
| combination. |
|
|
PORT ID | Allows you to position where the Port ID appears on the |
DISPLAY | monitor. The default is the upper left corner, but you can have |
POSITION | it appear anywhere on the screen. |
| Use the Mouse or the Arrow Keys plus Pg Up, Pg Dn, Home, |
| End, and 5 (on the numeric keypad with Num Lock off), to |
| position the Port ID display, then Click or press [Enter] to lock |
| the position and return to the Set submenu. |
|
|
PORT ID | Determines how long a Port ID displays on the monitor after a |
DISPLAY | port change has taken place. The choices are: User Defined - |
DURATION | which lets you select the amount of time (from 1 - 255 sec.); |
| and Always On - which displays the Port ID at all times. If you |
| select User Defined, key in the number of seconds, then press |
| [Enter]. The default is 3 Seconds. A setting of 0 (zero) |
| disables this function. |
|
|
(Table continues on next page)