VM1616T User Manual

Switch Port Commands

The formulas for Switch Port commands are as follows:

1.Switch Command + Input Command + Port number + Output Command + Port Number + Address + Device Number + Control + [Enter]

For example, to switch input port 02 (audio and video) to output port 05 on device 01, type the following:

sw i02 o05 a01 [Enter]

2.Switch Command + Output Command + Port Number + Address + Device Number + Control + [Enter]

For example, to turn off video output on port 03, type the following: sw O03 a00 video off [Enter]

3.Switch Command + Output Command + Port Number + Address + Device Number + Control + [Enter]

For example, to switch the next output to the local port, type the following: sw l1 + a00 [Enter]

Possible Values

The following table shows the possible values for switch commands:

Command

Description

 

 

sw

Switch command

 

 

 

 

Input Command

Description

 

 

i

Input command

 

 

 

 

Input Port Number

Description

 

 

xx

01-16 port (default is 01)

 

 

 

 

Output Command

Description

 

 

o

Output command

 

 

 

 

Output Port Number

Description

 

 

yy

01-16 port (default is 01)

 

 

l1

Local output port

 

 

*

All output ports

 

 

48