Chapter 5. RS-232 Commands

Save/Load Profile Commands

The formulas for Save/Load Profile commands are as follows:

1. Command + Profile + Number + Address + Number + Control + [Enter]

For example, to save the current connection configuration to profile 12 on device 01, type the following:

profile f 12 a01 save [Enter]

2. Command + Profile + Number + Address + Number + Control + [Enter]

For example, to load profile 12 on device 01, type the following: profile f 12 a01 load [Enter]

The following tables show the possible values for commands:

Profile

Description

 

 

f

Profile

 

 

 

 

Command

Description

 

 

profile

Save / Load profile

 

 

 

 

Profile

Description

Number

 

 

 

yy

00-31 (default is 00)

 

 

 

 

Address

Description

 

 

a

Device address

 

 

 

 

Device

Description

Number

 

 

 

zz

00-15 (default is 00)

 

 

*

All devices

 

 

 

 

Control

Description

 

 

save

Save the current connection

 

configuration

 

 

load

Load a saved profile

 

 

51