7.2 Diagnostic commands

The commands in this section only provide information about the ATTO FibreCenter 3400. Access this information using these command line interface commands in a Telnet session over the Ethernet port.

Status

Displays the status of the power supplies and the cooling fans.

Limits:

PP= power supply status; OK = operating, NG=inoperable, NI = missing FF = cooling fan status: OK = operating

K = L

Action: none

Information: get•Status•000

 

Return syntax: Status•000•PS1:PP•FAN1:FF•PS2:

 

PP•FAN2:FF•KEY:K

 

Return example:

 

Status•000•PS1:OK•FAN1:OK•PS2:OK•FAN2:OK•KEY:L

Telnet Status

Returns the Telnet status.

Limits: Status may be narrowed to [1] Telnet session information [2] TCP statistics or [3] Telnet auditing information

Action: none

Information: get•RACK •000•Telnet•Status• [123]

Version

Displays the firmware version of the rack. The FibreCenter 3400 has two processors. Returns reflect status of the ARM firmware and the Xilinx firmware.

Limits: n = ARM firmware version; x = Xilinx firmware version

Action: none

Information: get•RACK •000•Version

 

Return: n.nn-xxx

Secure Data Path Applicationv 16

Page 21
Image 21
ATTO Technology 3400 operation manual Diagnostic commands, Status, Version