AXIS 2100 User’s Guide Technical Specifications 65

Appendix F - Technical Specifications
System Requirements - TCP/IP on Windows 95, 98, NT and 2000, as well as Linux, UNIX,
Mac and several others. Microsoft Internet Explorer 4.x, or higher (used with Axis’ A ctiveX
component AXIS Camera Control), or Netscape 4.x or higher.
Network Connection - RJ45 twisted pair cable, or remote connection using any standard
serial modem.
Networking - 10baseT Ethernet or 100baseTX Fast Ethernet, TCP/IP, HTTP, FTP, SMTP, NTP,
ARP and BOOTP.
I/O Connector - 1 optical-isolated alarm input. 1 digital output (max 24V, 100mA) with
programmable digital input/output for remote image storage via FTP or SMTP, pre/post
alarm image storage.
Image Updating - Up to 10 frames/second over 10Mbps or 100Mbps networks.
Pre/Post Alarm Buffer - Up to 500kB memory available for pre/post alarm image storage.
Modem Connector - Single 9-pin D-SUB RS-232 connector, max 115 kbps, half duplex
Operating Conditions: - Temp: 40o to 105o F (+5o to +40o C), Humidity: 20-80% RHG.
Approvals - EMC: FCC Class A, EN 55022/1994, EN55024/1998
Safety: EN 60950, UL, CSA.
Metrics: - Height: 1.6” (4.3 cm), Width: 4.0” (10.2 cm), Length: 5.8” (14.7 cm), Weight: 0.55
lb. (0.25 kg) excluding power supply.
Hardware - ARTPEC-1 compression chip; ETRAX-100, including, 32 bit RISC, 100 MIPS
CPU, 8 MB RAM, 2 MB FLASH PROM.
Power - External power supply 12V AC, 9.6 VA (PS-D, included), 9-15V AC, min. 10VA, or
9-15V DC, min. 7W.