Hardware Description
Control button
Network connector with Network and Power Indicators
AXIS 231D+/232D+ - Description 7
Connection module connector
Mounting slot for fixing screw
Serial number S/N
Network Connector- After completion of the startup and self test routines, the Network and Power Indicators on the network connector flashes as follows:
Indicator | Color | Description |
Network | Green | Flashes for network activity |
|
|
|
Power | Green | Normal operation |
|
|
|
| Amber | Flashes green/amber during upgrade and when connecting to |
|
| AXIS Internet Dynamic DNS Service |
|
|
|
Detail - network connector:
Power
Indicator
Network
Indicator
Control Button - Press this button to restore the factory default settings, as described in Resetting to Factory Default Settings, on page 48. The Serial Number (S/N) is located on the label on the unit.
Network Connector - The AXIS 231D+/232D+ connects to the network via a standard RJ45 connector. Supporting NWAY, the AXIS 231D+/232D+ detects the speed of the local network segment (10BaseT/100BaseTX Ethernet).
Connection Module - The connection module provides the physical interface to 4 transistor outputs, 4 digital inputs and is the connection point for AC power. See Connection Module, on page 50.
For instructions on how to install the AXIS 231D+/232D+, please refer to the Installation Guide which is supplied with the product in printed format or in PDF format from the Axis Web site at http://www.axis.com
4 outputs
4 inputs
AC Power
Connection module connector