1.3Component Location and Description

MAC2000

Introduction

1.3Component Location and Description

MAC2000 Control Panel

High Side Gauge Shows the pressure in the high side of the vehicle’s A/C system.

Low Side Gauge Shows the pressure in the low side of the vehicle’s A/C system.

LCD Display (Screen) – Displays all operational, error, and maintenance messages.

Refrigerant Identifier Filter Protects the refrigerant identifier sensor from contaminants.

Printer Provides a printed record of the functions performed by the MAC2000. The printer can print the record of the MAC2000’s last operation as well as other refrigerant management data and operational statistics.

Start Key – Press to start a function.

Pause/Reset Key – Press to either pause, reset, or abort a function and return the display to the Main menu.

Enter Key – Press to accept a value as displayed on the screen.

Weight Convert Key – Press to change the charge amount between pounds, pound & ounces, and kilograms. Pushing this key allows a technician to scroll through the different weight units.

Arrow Keys Use these keys to select variables and adjust values such as charge weight and vacuum time. The Increase and Decrease keys are used to adjust numerical values, while the Back, Forward, Left and Right keys are used to move between values displayed on the screen.

F1 – F5 Function Keys Use these keys to select various modes and functions on the MAC2000. A key’s current function is described directly above it on the screen.