Bacharach 2072-0400 Recovery, Vacuum, Charge, Snapshot, Next, menu, Main, System, Tank, refill

Models: 2072-0400

1 40
Download 40 pages 52.22 Kb
Page 18
Image 18
Recovery

Operation

MAC2000

Main Menu

Recovery

Vacuum

Charge

Snapshot

Next

mode

mode

mode

mode

menu

 

 

 

 

 

Recovery mode Recovers and recycles refrigerant from a vehicle’s A/C system. This mode is most often used prior to opening an A/C system to atmosphere to replace a system component.

Vacuum mode – Removes residual air and moisture from a system previously opened to the atmosphere. This mode also allows a technician to verify that the A/C system will hold a vacuum for a certain length of time.

Charge mode – Select this mode to add refrigerant to an A/C system; also most commonly used to “top off” the system.

Snap-Shot mode – Monitors and records important operating information including the high- and low-side pressures, ambient temperatures, A/C vent temperatures, ambient humidity, and (optionally) vent air flow velocities. This information is used to diagnose and measure A/C performance before and after service.

Next menu Displays Menu 2.

Menu 2

Main

System

Tank

System

Next

menu

flush

refill

set-up

menu

 

 

 

 

 

Main menu Returns display to the Main menu.

System flush Removes all oil and refrigerant from an A/C system. This mode is often used prior to retrofitting a system to R-134a.

Tank refill – Overrides the automatic tank refill function of the MAC2000 and transfers refrigerant from the external source tank to the internal storage tank.

System set-upSets up certain operating parameters in order for the MAC2000 to operate correctly. The set-up information must be entered prior to operating the MAC2000.

Next menu Displays Menu 3.