MAC2000 | Operation |
Perform a refrigerant identity check as follows:
1.If not already done, plug the MAC2000 into a properly grounded AC outlet; set the Power switch to ON; then wait until the unit completes its self diagnostics. The screen will display “Select mode” when ready.
2.Press the Next menu function key twice to display Menu 3. Then press the Identify mode function key.
3.Hook up the service hoses, open the A/C system’s
4.Press Reset to exit the identification screen.
5.Close
6.Press Start to begin recovering the hoses. During the recovery process the message “Clearing hoses, please wait . . .” is displayed. After recovery is complete, the Main menu will appear.
3.11Check Internal Tank for Air
When the MAC2000 remains turned ON during the day, air is automatically purged from the internal storage tank. A technician, however, can manually check and purge the internal tank of air and any other
1.If not already done, plug the MAC2000 into a properly grounded AC outlet; set the Power switch to ON; then wait until the unit completes its self diagnostics. The screen will display “Select mode” when ready.
2.Press the Next menu function key twice to display Menu 3. Then press the Check Tank Air function key.
3.Press the Start key. The refrigerant identifier will first warm up, zero itself, and then display the message “Analyzing sample, please wait …” When complete, the results of the identification process will be displayed.
Instruction | 27 |