BAD BOY™ SPOT LUMINAIRE USER MANUAL
ii 02.9812.0001C
WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXPOSURE TO EXCESSIVE
ULTRAVIOLET RADIATION
1. PRG luminaires may use an HID type lamp which produces UV radiation. DO NOT look directly at lamp.
2. It is hazardous to operate luminaires without complete lamp enclosure in place or when lens is damaged.
Lenses or UV shields shall be changed if they have become visibly damaged to such an extent that their
effectiveness is impaired.
WARNING: INSTRUCTIONS FOR PROTECTION AGAINST INJURY TO PERSONS
1. Exterior surfaces of the luminaire will be hot during operation. Use appropriate safety equipment (gloves,
eye protection, etc.) when handling and adjusting hot equipment and components. Service and maintenance
should be performed only by qualified personnel as determined by the high pressure lighting fixture
manufacturer.
2. Arc lamps generate intense heat. Disconnect power and allow lamp to cool for 5 minutes before relamping.
3. Arc lamps emit ultraviolet radiation which can cause serious skin burn and eye inflammation. Additionally,
arc lamps operate under high pressure at very high temperatures. Should the lamp break, there can exist a
danger of personal injury and/or fire from broken lamp particles being discharged.
4. The lamp shall be changed if it has become damaged or thermally deformed.
5. If lamp is touched with bare hands, clean lamp with denatured alcohol and wipe with lint-free cloth before
installing or powering up the luminaire.
6. Serious injury may result from the generation of ozone by this lamp system. A proper means of venting must
be provided.