Features & Specifications
| 
 | Model | 
 | TS25 | TS45 | TS80 | TS130 | TS175 | |
| 
 | Standby output– | 1500C Rise | 
 | 
 | 
 | 
 | 
 | |
| 
 | (KVA/KW): | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 3 PH @ 480 Volt | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 25/20 | 48/38 | 81/65 | 134/107 | 175/140 | |||
| 
 | 3 PH @ 208/240 Volt | 25/20 | 46/37 | 72/58 | 131/105 | 169/135 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 1 PH @ 240 Volt | 18/18 | 27/27 | 45/45 | 70/70 | 80/80 | ||
| 
 | Continuous Output– | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 1250C Rise (KVA/KW): | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 3 PH @ 480 Volt | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 23/18 | 44/35 | 75/60 | 121/97 | 169/135 | |||
| 
 | 3 PH @ 208/240 Volt | 23/18 | 44/35 | 69/55 | 119/95 | 156/125 | ||
| 
 | 1 PH @ 240 Volt | 
 | 
 | 
 | 
 | 
 | ||
| G | 18/18 | 25/25 | 43/43 | 66/66 | 75/75 | |||
| E | Voltage – 3 PH Adjustable | 208/220/240/ | 208/220/240/ | 208/220/240/ | 208/220/240/ | 208/220/240/ | ||
| N | 
 | 
 | 416/440/460/480 | 416/440/460/480 | 416/440/460/480 | 416/440/460/480 | 416/440/460/480 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| E | 
 | 
 | 
 | 
 | 
 | 
 | ||
| Voltage – 1 PH Adjustable | 120/127/139/ | 120/127/139/ | 120/127/139/ | 120/127/139/ | 120/127/139/ | |||
| R | 
 | 
 | 240/254/277 | 240/254/277 | 240/254/277 | 240/254/277 | 240/254/277 | |
| A | Amperage (Continuous): | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | ||||
| T | 3 PH 480 Volt | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 27.1 | 52.6 | 90.2 | 145.8 | 203.0 | |||
| O | 3 PH 208 Volt | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 62.5 | 121.4 | 190.8 | 329.6 | 433.7 | |||
| R | 3 PH 240 Volt | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 54.1 | 105.3 | 165.4 | 285.7 | 375.9 | |||
| 
 | 1 PH 240 Volt/120 Volt | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 75.0/150.0 | 104.2/208.3 | 179.2/358.3 | 275/550 | 312.5/625.0 | |||
| 
 | Receptacles: | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 120 Volt, 15 Amp GFCI | 4 | 6 | 6 | 6 | 6 | ||
| 
 | 120/240 Volt, 50 Amp, | 2 | 3 | 3 | 3 | 3 | ||
| 
 | CS6369 Twistlock | 
 | 
 | 
 | 
 | 
 | ||
| 
 | Voltage Regulation 1/2% | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 1/2% | 1/2% | 1/2% | 1/2% | 1/2% | |||
| 
 | Power Factor – 3 Phase | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 0.8 | 0.8 | 0.8 | .08 | .08 | |||
| 
 | Frequency | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 50 or 60 Hertz | 50 or 60 Hertz | 50 or 60 Hertz | 50 or 60 Hertz | 50 or 60 Hertz | ||
| 
 | Total Harmonic Distortion | 
 | 
 | 
 | 
 | 
 | ||
| 
 | <5% | <5% | <5% | <5% | <5% | |||
| 
 | Insulation | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Class F | Class F | Class F | Class F | Class F | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | Engine Make/Model | Isuzu | Isuzu | John Deere | John Deere | John Deere | ||
| 
 | 
 | 
 | 4LE | 4BG1 | TO4045T | TO6068 | RG6081T | |
| 
 | Design | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Water Cooled | Water Cooled | Water Cooled | Water Cooled | Water Cooled | ||
| 
 | 
 | 
 | 4 Cycle Diesel | 4 Cycle Diesel | 4 Cycle Diesel | 4 Cycle Diesel | 4 Cycle Diesel | |
| 
 | Starting System | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 12 VDC | 12 VDC | 12 VDC | 12 VDC | 12 VDC | |||
| 
 | Displacement (cid) | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 133.0 | 264.2 | 276.0 | 414.0 | 498.0 | |||
| 
 | Cylinders | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 4 | 4 | 4 | 6 | 6 | ||
| 
 | HP @ Rated Speed | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 34.5 | 64.0 | 100.0 | 166.0 | 211.0 | |||
| 
 | RPM | 
 | 
 | 
 | 
 | 
 | 
 | |
| E | 
 | 1800 | 1800 | 1800 | 1800 | 1800 | ||
| Safety Shutdowns: | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | ||||
| N | 
 | 
 | 
 | 
 | 
 | |||
| High Temperature | Std. | Std. | Std. | Std. | Std. | |||
| G | ||||||||
| Low Oil | 
 | Std. | Std. | Std. | Std. | Std. | ||
| I | 
 | |||||||
| Overspeed | 
 | Std. | Std. | Std. | Std. | Std. | ||
| N | Overcrank | 
 | Std. | Std. | Std. | Std. | Std. | |
| E | Fuel Capacity | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 50 | 80 | 80 | 160 | 160 | |||
| 
 | Fuel Consumption (GPH): | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 1/2 Load | 
 | 1.3 | 2.0 | 2.7 | 4.2 | 5.6 | |
| 
 | Full Load | 
 | 2.0 | 3.4 | 4.9 | 8.1 | 10.5 | |
| 
 | Approx. Run Time (Hrs.): | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 1/2 Load | 
 | 38 | 40 | 30 | 38 | 29 | |
| 
 | Full Load | 
 | 25 | 24 | 16 | 20 | 15 | |
| 
 | Battery Recommendation Min. Cold | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 750 | 900 | 900 | (2) 750 | (2) 750 | |||
| 
 | Cranking Amps | 
 | 
 | 
 | 
 | 
 | ||
| 
 | (Battery not included) | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | Dimensions (L x W x H): | 
 | 
 | 
 | 
 | 
 | ||
| 
 | With Trailer | 
 | 123” x 62” x 70” | 139” x 60” x 81” | 139” x 60” x 81” | 163” x 66” x 94” | 163” x 66” x 94” | |
| 
 | Without Trailer | 74” x 38” x 52” | 84” x 38” x 61” | 84” x 38” x 61” | 108” x 42” x 74” | 108” x 42” x 74” | ||
| 
 | Weight (Lbs.): | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | Without Fuel | 
 | 2265 | 3540 | 3848 | 5600 | 6200 | |
| 
 | Without Fuel & Trailer | 1790 | 2829 | 3053 | 4610 | 5205 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
7