Farm Duty 1-Phase

Model: DLC25

 

 

Baldor

POWER SYSTEMS

4 Cycle Diesel Liquid Cooled

Assembled in USA

Standby Power Ratings

60Hz kW 27.5 kVA 27.5

Continuous Power Ratings

60Hz

kW 25 kVA 25

Baldor Generator Features

 

Options

 

 

 

 

 

 

 

 

 

Exhaust silencer: Critical

 

 

 

 

 

Baldor generators are manufactured in a certified

 

 

 

 

 

 

ISO9001 facility located in Oshkosh, Wisconsin.

 

Single wall sub base fuel tank

 

 

 

 

 

 

 

 

 

 

 

Double wall UL 142 approved sub-base fuel tank

Every generator is design, prototype, and

 

production tested

 

Battery charger 12V float

 

 

 

 

 

 

 

 

 

 

 

 

 

Line circuit breaker

 

 

 

 

 

Brushless synchronous four-pole alternator

 

 

 

 

 

 

 

Flexible fuel lines

 

 

 

 

 

 

Industrial grade exhaust silencer

 

 

 

 

 

 

 

 

Weather protective enclosure

 

 

 

 

Engine block heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baldor gensets attain one step load acceptance

 

 

 

 

 

 

 

 

 

 

 

of nameplate rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Generator Ratings

 

 

 

 

 

PowerPAC 4 controller includes low oil pressure

 

 

 

 

 

 

shutdown, high coolant temperature shutdown,

 

 

 

 

 

 

 

 

 

 

 

overspeed and overcrank indicators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150￿C Rise

125￿C Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standby Rating

Continuous Rating

Flexible exhaust connection

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

PH

Hz

 

kW/kVA

Amps

kW/kVA

 

Amps

 

 

 

Battery rack and cables

 

 

 

 

 

 

 

 

 

 

 

120/240

1

60

 

27.5/27.5

114.6

25.0/25.0

 

104.2

 

 

 

 

Installation and operation manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Worldwide network of parts and service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ratings: - Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage. Primary power to the installation is

utility supplied. No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS55114, DIN 6271. Continuous Power Rating: Continuous power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of operation. Prime power ratings in accordance with

ISO 3046, BS55114, DIN 6271. For additional information, please consult factory. Manufacturer reserves the right to implement specifications or design changes without notice. Single phase: Single phase units are rated at 1.0 (Unity) power factor. WARNING: Do not connect generator to any building's electrical system unless a

disconnect switch has been installed.