Farm Duty | Model: DLC25 |
|
|
Baldor
POWER SYSTEMS
4 Cycle Diesel Liquid Cooled
Assembled in USA
Standby Power Ratings
60Hz kW 27.5 kVA 27.5
Continuous Power Ratings
60Hz
kW 25 kVA 25
Baldor Generator Features |
| Options |
|
|
|
|
|
|
|
| |
✓ |
| ■ Exhaust silencer: Critical |
|
|
|
|
| ||||
■ Baldor generators are manufactured in a certified |
|
|
|
|
|
| |||||
ISO9001 facility located in Oshkosh, Wisconsin. |
| ■ Single wall sub base fuel tank |
|
|
|
| |||||
|
|
|
|
|
| ||||||
✓ |
| ■ Double wall UL 142 approved | |||||||||
■ Every generator is design, prototype, and |
| ||||||||||
production tested |
| ■ Battery charger 12V float |
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||
✓ |
| ■ Line circuit breaker |
|
|
|
|
| ||||
■ Brushless synchronous |
|
|
|
|
|
| |||||
✓ |
| ■ Flexible fuel lines |
|
|
|
|
|
| |||
■ Industrial grade exhaust silencer |
|
|
|
|
|
|
| ||||
✓ |
| ■ Weather protective enclosure |
|
|
|
| |||||
■ Engine block heater |
|
|
|
|
| ||||||
✓ |
|
|
|
|
|
|
|
|
|
|
|
■ Baldor gensets attain one step load acceptance |
|
|
|
|
|
|
|
|
|
|
|
of nameplate rating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
✓ |
| Generator Ratings |
|
|
|
|
| ||||
■ PowerPAC 4 controller includes low oil pressure |
|
|
|
|
|
| |||||
shutdown, high coolant temperature shutdown, |
|
|
|
|
|
|
|
|
|
|
|
overspeed and overcrank indicators |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 150C Rise | 125C Rise |
|
| |||
|
|
|
|
|
|
|
| ||||
✓ |
|
|
|
|
| Standby Rating | Continuous Rating | ||||
■ Flexible exhaust connection |
|
|
|
|
|
|
|
|
|
|
|
| Voltage | PH | Hz |
| kW/kVA | Amps | kW/kVA |
| Amps | ||
✓ |
|
|
| ||||||||
■ Battery rack and cables |
|
|
|
|
|
|
|
|
|
|
|
120/240 | 1 | 60 |
| 27.5/27.5 | 114.6 | 25.0/25.0 |
| 104.2 |
| ||
✓ |
|
|
| ||||||||
■ Installation and operation manual |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
✓ |
|
|
|
|
|
|
|
|
|
|
|
■ Worldwide network of parts and service |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ratings: - Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage. Primary power to the installation is
utility supplied. No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS55114, DIN 6271. Continuous Power Rating: Continuous power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of operation. Prime power ratings in accordance with
ISO 3046, BS55114, DIN 6271. For additional information, please consult factory. Manufacturer reserves the right to implement specifications or design changes without notice. Single phase: Single phase units are rated at 1.0 (Unity) power factor. WARNING: Do not connect generator to any building's electrical system unless a
disconnect switch has been installed.