2. Xeno nb ulb lamp replacement process
2.1 Removal of the lamp house
WARNING:This proceduremay only be performed by qualied technical service personnel.
CAUTION:Lampca sing is very hot after operation. To avoid burns, let the projector cool down for at least 15
minutes before proceeding to the lamp unit replacement.
CAUTION:Due to its high internal pressure, the lamp may explode in either hot or coldst atesif improperly
handled.
Necessary tools
7mmat screw driver.
How to remove the lamp house of the projector ?
1. S witch offthe projector.
2. R emove the lamp cover.
3. Release the three spring lock screws of the lamp house as illustrated.
Image2-1
4. Hold fast the lamp house by the handles and pull the lamp house out of the projector.
Caution: Beware of the weight of the lamp assembly. Takethe necessary precautions to avoid personal injury.
Image2-2
5. P lacethe lamp house on a stable support.
8R59770175 XENONBULB LAMP REPLACEMENT 24/09/2008