2. Xeno nb ulb lamp replacement process
2.5 Resetting the lamp parameters

CAUTION:The“LA MP INFO” parameters which are stored on a chip MUST be updated after each installation

ofan x enon bulb lamp inside the lam p house. Ne glecting this update will result in po or performance and short
life time ofthe xenon bulb lamp.

How to reset the lamp parameters?

1. Start up the projector but do not ignite the lamp.
2. Go via the Communicator touch panel to the menu “Installation”>“Lamp”>“Lamp information”.
3. While the Lamp information window is displayed, tip on Reset (1).
A reset message is displayed (2).
4. Fill out the article number of the new lamp (3a)
Or,
clickon Select (3b) to display a list of possible article numbers (4). Select a article number (5) and click OK (6).
The software will check if the entered article number is a valid number (7).
5. Fill out the serial number of the lamp (8).
6. C lick Reset (9).
Image2-19
Resetlamp info

CAUTION:For more informationabout using the Communicator touch panel consult the user’s guide of the

communicator touch panel.
20 R59770175 XENONBULB LAMP REPLACEMENT 24/09/2008