2. X enon bulb lamp replacement process
2.6 Realignment of the lamp in its reector
Each xenon bulb lamp installation requires a realignmentof the lamp in its reector for optimal performance
of the xenon bulb lamp in the DP-1200/DP-1500/DP-2000 projector. Furthermore, it is recommended to realign
the lamp after the rst run time of 100 and 200 hours. Especially the Z-axis of the lamp.

WARNING:This proceduremay only be performed by qualied technical service personnel.

How to realign the lamp in its reector?

1. Remove the cover of the lamp compartment to gain access to the X-, Y-, and Z-axis adjustment thumbscrews of the lamp.
2. Switch on the projector and start up the lamp.
3. Go via the Communicator touch panel to the menu “Installation” >“Lamp” >“Light output”.
4. Set the “Light output mode”innormal mode and the “Lamp Dimming” on maximum (255).
Note: This window on the Communicator touch panel shows in the upper left corner the measured value of the built-in light
sensor of the projector.
Image2-20
5. Release the X-axis lock thumb screw (ref LX image 2-21) and Y-axis lock thumb screw (ref LY image 2-21).
6. Adjust the X-axis (ref X image 2-21), the Y-axis (ref Y image 2-21) and the Z-axis (ref Z image 2-21) for maximum current light
output (Footlambert Measured). Carefully turn the thumbscrew for maximum light output. Once over the maximum, turn slightly
in opposite direction to reach the maximum light output again. Do this for each direction and minimum repeat this adjustment
cycle twice.
R59770175 XENONBULB LAMP REPLACEMENT 24/09/2008 21