1. Xenon b ulb lamp
1. XENON BULB LAMP
Safety
Read all warnings and cautions attentively.This to preven tpersonal injury while installing an xenon bulb lamp in the lamp house of
theDP-1200/DP-1500/DP-2000 digital cinema projector. Afterthis chapter, additional “warnings” and “cautions” are given depending
on the installation procedure. Read and follow these “warnings” and “cautions” as well.
WARNING:DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON BULB LAMP HANDLING OR SERVICE.
CAUTION:Xenoncompact arc lamps are highly pressurized. When ignited, the normal operating temperature
ofthe bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped
or otherwise mishandled. Whenever the lamp house, containing a xenon bulb lamp, has to be dismantled or
wheneverthe protective container or cloth has t o be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
WARNING:Always wear face protection (full face shield with neck protector) when handling xenon bulb
lamps.
WARNING:Always wear protective clothing (welder’sjacket) when handling xenon bulb lamps.
WARNING:Always wear clean leather gloves with wrist protectorswhen handling xenon bulb lamps.
CAUTION:Expired xenon bulblamps.
Dispose of expired bulbs that are beyond warranty in the following manner: wrap the bulb tightly in several
layers of canvas or heavy cloth. Place it on hard surface and shatter the envelope with a sharp hammer blow.
DO NOT place a non shattered bulb in any ordinary refuse container.
Whenreturning a xenon bulb lamp for warrantyadjustment, pack it in its original shippingcontainer. Complete
and return allrequired warranty information.
Overview
• Introduction
Supported xenon bulb lamps
R59770175 XENONBULB LAMP REPLACEMENT 24/09/2008 3