2. Xeno nb ulb lamp replacement process
2.2 Removal of the xenon bulb lamp
WARNING:DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON BULB LAMP HANDLING OR SERVICE.
WARNING:This proceduremay only be performed by qualied technical service personnel.
CAUTION:Xenoncompact arc lamps are highly pressurized. When ignited, the normal operating temperature
ofthe bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped
or otherwise mishandled. Whenever the lamp house, containing a xenon bulb lamp, has to be dismantled or
wheneverthe protective container or cloth has t o be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
WARNING:Always wear face protection (full face shield with neck protector) when handling xenon bulb
lamps.
WARNING:Always wear protective clothing (welder’sjacket) when handling xenon bulb lamps.
WARNING:Always wear clean leather glovesw ithwrist protectors when handling xenon bulb lamps.
Necessary tools
4 mm Allen wrench.
17 mm open ended spanner (2 pieces).
How to remove the xenon lamp bulb from the lamp house?
1. Ensure that you wear protective clothing, a full face shield and protective gloves.
2. Remove rst the lamps house side cover and then the lamp house UV blocker assembly by releasing the retaining thumbscrews
as illustrated. Support the xenon bulb lamp while removing the UV blocker assembly.
12
Image2-3
10 R59770175 XENONBULB LAMP REPLACEMENT 24/09/2008