2. Xeno nb ulb lamp replacement process
Image2-8
3. Install the lamp cathode adaptor (A) upon the xenon bulb lamp (L) as illustrated. Use torque 2,5 Nm to fasten the xation screw
(S)oftheadapter. Useforthatatorquewrenchwitha5mmAllensocket. Makesurethatthereisfullcontactbetweenthe
cathode adapter and the lamp base.
Note: The cathode lamp adaptor is delivered in a separate bag with the projector. In case of a lamp replacement you have to
reuse the adaptor from thexeno nbulb lamp which you want to replace.
S
L
A
2,5 Nm
Image2-9
4. Install the anode wire lug (L) upon the anode socket (S). Hold fast thenut N1 with an open-end wrench while fastening the nut N2
with a torque of9Nmusinga torque wrench. Ensure that at both sides of the wire lug L a plane washer (W1 & W2) is present.
Note: Theanode socket is located just below the UV blocker and can easily be removed from the lamp house. In caseof a lamp
replacement you have to reuse the anode socket which is connectedt o the xenonbulb lamp which you want to replace.
14 R59770175 XENONBULB LAMP REPLACEMENT 24/09/2008