Reference Guide for the Model RM356 Modem Router

Diagnostic Menu

The diagnostic menu allows you to test several functions of your router. From the Main Menu, enter 24 to display Menu 24 - System Maintenance. Enter 4 to display Menu 24.4 - System Maintenance - Diagnostic.

The diagnostic tools described in this section allow the user to perform the following functions:

Test the ISP connection

Communicate directly with the MODEM port

Test the TCP/IP configuration

Reboot the system

Change the interface mode to command-line mode

The diagnostic test options from Menu 24.4 - System Maintenance - Diagnostics are listed in Table 9-5.

Table 9-5.

System Maintenance - Diagnostic Menu Fields

 

 

 

 

Field

 

Command

Description

 

 

 

 

MODEM

 

 

 

Drop MODEM

 

1 [Enter]

This command hangs up the current MODEM call.

Reset MODEM

 

2 [Enter]

This command will reset the MODEM.

Manual Call

 

3 [Enter]

This command will cause the router to place a manual call to a Remote

 

 

 

Node and log in to the account. A trace will be displayed on the screen

 

 

 

showing the progress of the call setup and protocol negotiation.

Redirect to

 

4 [Enter]

This command will redirect the Manager terminal to the MODEM port

MODEM

 

 

so that AT commands may be sent directly to the internal MODEM.

 

 

 

 

TCP/IP

 

 

 

Internet Setup

 

11 [Enter]

This command will cause the router to place a manual call to the ISP

Test

 

 

and log in to the account. A trace will be displayed on the screen

 

 

 

showing the progress of the call setup and protocol negotiation.

Ping Host

 

12 [Enter]

This test pings the host, which determines the functionality of the

 

 

 

TCP/IP protocol on your system.

 

 

 

 