Bay Technical Associates RM356 manual Command Interpreter Mode, Call Control

Models: RM356

1 118
Download 118 pages 62.5 Kb
Page 100
Image 100

Reference Guide for the Model RM356 Modem Router

To update the RAS software:

1.Select Menu 24 - System Maintenance.

2.Enter 7 to select Software Update.

3.Enter 1 to select Load RAS code.

A message is displayed showing further instructions and asking if you want to continue.

4.Press y and wait for the Debug Mode command prompt.

5.Enter the command atur and wait.

After about 30 seconds, the router displays the Starting XMODEM upload... message.

6.Transfer the new software file to the router using the XMODEM Protocol of your serial communications software.

7.Enter the command atgo to restart the router when the router displays the OK message.

Note: NETGEAR recommends that you change the Manager port baud rate to 38400 before updating the software. Doing so results in an update time of 5 to 10 minutes.

Command Interpreter Mode

Select option 8 from Menu 24 - Maintenance to enter the command interpreter mode. This mode allows you to diagnose, test, and configure your router using a script or specified set of commands. A list of valid commands can be found by typing help at the command prompt. For more detailed information, check the NETGEAR Web site at http://netgear.baynetworks.com.

Call Control

The Model RM356 Modem Router provides call control management functions for the remote node and remote dial-in user. These functions are budget management, blacklist, and call history, which are on the Call Control menu. Select option 9 from Menu 24 to display the Call Control menu.

9-10

System Maintenance

Page 100
Image 100
Bay Technical Associates RM356 manual Command Interpreter Mode, Call Control