Table 6-1 lists and describes the fields in the Default Dial-in Setup menu and explains how to configure the protocol-independent fields in this menu.

Table 6-1.

Fields in Menu 13 - Default Dial-in Setup

 

 

 

Field

 

Description

 

 

 

Telco Options:

 

 

CLID Authen

 

This field sets the CLID authentication parameter for all incoming calls.

 

 

The three options for this field are:

 

 

None—No CLID is required (default).

 

 

Required—You must provide the CLID, or the call is disconnected.

 

 

Preferred—If the CLID is available, it is used to do authentication. If the

 

 

CLID is not available, the call continues.

 

 

 

PPP Options:

 

 

Recv Authen

 

This field sets the authentication protocol used for incoming calls.

 

 

The four options for this field are:

 

 

CHAP/PAP—The router tries CHAP first, but PAP is used if CHAP is not

 

 

available (default).

 

 

CHAP—Use CHAP only.

 

 

PAP—Use PAP only.

 

 

None—No authentication is required.

Compression

 

This field allows the negotiation of data compression with the equipment of

 

 

the dial-in user.

Mutual Authen

Some vendors (for example, Cisco Systems) implement a type of mutual

 

 

authentication. That is, the node that initiates the call requests a user

 

 

name and password from the far end that it is dialing to. If the remote node

 

 

that is dialing in implements this type of authentication, set this field to Yes.

 

 

Choose one of the following for setting PAP:

 

 

• PAP Login—This field is enabled only if the Mutual Authen field is

 

 

set to Yes. Enter the login name to be used to respond to the PAP

 

 

authentication request of the far end. This field does not apply to CHAP

 

 

authentication.

 

 

• PAP Password—This field is enabled only if the Mutual Authen field is

 

 

set to Yes. Enter the PAP password to be used to respond to the

 

 

authentication request of the far end. This field does not apply to CHAP

 

 

authentication.

 

 

Callback Budget Management:

 

Allocated Budget (min)

This field sets a budget callback time for all the remote dial-in users.

 

 

The default for this field is 0 for no budget control.

Period (hr)

 

This field sets the time interval to reset the above callback budget control.

 

 

 

6-2

Dial-In Configuration

Page 66
Image 66
Bay Technical Associates RM356 manual Fields in Menu 13 Default Dial-in Setup, Field Description

RM356 specifications

Bay Technical Associates RM356 is a state-of-the-art remote monitoring solution designed for a wide range of industries. It is particularly suited for companies requiring a reliable system for tracking and monitoring operations in real-time. This advanced device combines innovative technologies to deliver unparalleled functionality and performance.

One of the standout features of the RM356 is its robust data acquisition capabilities. The device can interface with various sensors and equipment, enabling it to collect critical data from multiple sources. This real-time data collection allows for immediate analysis and facilitates informed decision-making. The RM356 supports various protocols and standards, making it highly compatible with existing infrastructure.

Another significant characteristic of the RM356 is its advanced communication technology. Equipped with both wired and wireless communication options, including LTE, Wi-Fi, and Ethernet, it ensures seamless connectivity in various environments. This versatility enables businesses to monitor operations remotely, reducing the need for on-site presence and enhancing operational efficiency.

The RM356 also incorporates cutting-edge analytics and reporting tools. Its built-in software allows users to visualize data through intuitive dashboards, making it easier to identify trends and anomalies. These analytics capabilities help organizations optimize processes and address potential issues before they escalate, ultimately improving productivity and reducing operational costs.

Security is a top priority for the RM356. The unit comes with robust encryption and authentication measures to ensure that the data it collects remains secure from unauthorized access. This feature is especially critical for industries handling sensitive information or operating in regulated environments.

Additionally, the RM356 is designed with user-friendliness in mind. Its installation process is straightforward, with comprehensive setup guides available for quick deployment. Once operational, users can easily navigate the system interface, allowing for efficient monitoring and management of their operations.

With its combination of advanced features, reliable communication, data analytics, and strict security measures, Bay Technical Associates RM356 stands out as an excellent choice for businesses looking to enhance their monitoring capabilities. Whether in manufacturing, logistics, energy, or other sectors, the RM356 is poised to deliver improved outcomes and support organizations in their quest for operational excellence.