Generic Filter Rule

This section provides information about configuring the protocol-independent parameters for a generic filter rule for your router. Table 8-5 lists the fields in the menu. When you complete Menu 21.1.1 - Generic Filter Rule, press [Enter] at the Press ENTER to Confirm... prompt to confirm your selections. Press [Esc] at any time to cancel your selections. The data entered is displayed on Menu 21.1 - Filter Rules Summary.

Table 8-5.

Generic Filter Rule Menu Fields

 

 

 

Field

 

Description

 

 

 

Active

 

In this field, you can make the filter rule active (Yes) or inactive (No).

 

 

 

Offset

 

Offset refers to the value of the byte that you want to use as your starting offset. That is,

 

 

in the data packet, at what point do you want to begin the comparison. The range for

 

 

this field is from 0 to 255. Default = 0.

 

 

 

Length

 

This field refers to the length (in bytes) of the data in the packet that the router should

 

 

use for comparison and masking. The starting point of this data is determined by Offset.

 

 

The range for this field is 0 to 8. Default = 0.

 

 

 

Mask

 

In this field, specify (in hexadecimal) the value that the router should logically qualify

 

 

and the data in the packet. Because length is given in bytes, enter a hexadecimal

 

 

number that is twice the specified length for numbers in this field. For example, if length

 

 

is 4, a valid Mask entry must have 8 hexadecimal numbers (1155ABF8).

 

 

 

Value

 

In this field, specify (in hexadecimal) the value that the router should use to compare

 

 

with the masked packet. The value should align with Offset. Because length is given in

 

 

bytes, you need to enter twice the length in hexadecimal numbers for this field. For

 

 

example, if length is 4, a valid Value entry must have 8 hexadecimal numbers

 

 

(1155ABF8). If the result from the masked packet matches Value, then the packet is

 

 

considered matched.

 

 

 

More

 

In this field, you can determine whether to pass the packet through the next filter rule

 

 

before an action is taken. There are two options for this field:

 

 

• Yes

 

 

• No (Default)

 

 

If Yes is selected for this field, Action Matched and Action Not Matched will be N/A.

 

 

 

Filter Configuration

8-7

Page 83
Image 83
Bay Technical Associates RM356 manual Generic Filter Rule Menu Fields

RM356 specifications

Bay Technical Associates RM356 is a state-of-the-art remote monitoring solution designed for a wide range of industries. It is particularly suited for companies requiring a reliable system for tracking and monitoring operations in real-time. This advanced device combines innovative technologies to deliver unparalleled functionality and performance.

One of the standout features of the RM356 is its robust data acquisition capabilities. The device can interface with various sensors and equipment, enabling it to collect critical data from multiple sources. This real-time data collection allows for immediate analysis and facilitates informed decision-making. The RM356 supports various protocols and standards, making it highly compatible with existing infrastructure.

Another significant characteristic of the RM356 is its advanced communication technology. Equipped with both wired and wireless communication options, including LTE, Wi-Fi, and Ethernet, it ensures seamless connectivity in various environments. This versatility enables businesses to monitor operations remotely, reducing the need for on-site presence and enhancing operational efficiency.

The RM356 also incorporates cutting-edge analytics and reporting tools. Its built-in software allows users to visualize data through intuitive dashboards, making it easier to identify trends and anomalies. These analytics capabilities help organizations optimize processes and address potential issues before they escalate, ultimately improving productivity and reducing operational costs.

Security is a top priority for the RM356. The unit comes with robust encryption and authentication measures to ensure that the data it collects remains secure from unauthorized access. This feature is especially critical for industries handling sensitive information or operating in regulated environments.

Additionally, the RM356 is designed with user-friendliness in mind. Its installation process is straightforward, with comprehensive setup guides available for quick deployment. Once operational, users can easily navigate the system interface, allowing for efficient monitoring and management of their operations.

With its combination of advanced features, reliable communication, data analytics, and strict security measures, Bay Technical Associates RM356 stands out as an excellent choice for businesses looking to enhance their monitoring capabilities. Whether in manufacturing, logistics, energy, or other sectors, the RM356 is poised to deliver improved outcomes and support organizations in their quest for operational excellence.