Figure 17 (continued) - 7600A/B alternate multi-zone connections with Indirect Domestic Hot Water (DHW)

*Additional zones can be added by duplicating the plumbing and wiring of zone 3, adding additional transformers as needed.

CONTINUED FROM PREVIOUS PAGE

Control Wiring (Option 1): 7600B only

1.Set “DHWP on ZR” (see programming section for instructions)

2.Set “C1 on BOTH” (see programming section for instructions)

3.Circulator-on delay will affect all zones. Circulator-off delay will have no effect.

4.Up to two 24 VAC zone valves can be powered with the 7600B. Add an additional transformer as shown for every two or less valves over the original two.

5. Ensure there are no jumpers between the terminals of the zone valves.

ZONE 3*

 

LOW VOLTAGE

 

THERMOSTAT

SK10038

TW

TR

L2 L1 C1 C2 ZC ZR B1 B2

NEUTRAL WHITE

120 VAC

BLACK

HOT FIELD/MFR. SUPPLIED SERVICE SWITCH

GENERAL

CIRCULATOR

CIRCULATOR

120 VAC

DHW ZONE 24 VAC ZONE VALVE

Honeywell

V8043F

TR TH

MTR

ZONE 1

LOW VOLTAGE

THERMOSTAT

ZONE 1

24VAC ZONE VALVE

Honewell

V8043F

TR

TH

TH/

 

 

TR

MTR

T

Z

TV

24 VAC GAS

IGNITION SYSTEM

ZONE 3*

24 VAC ZONE VALVE

Honewell

V8043E, V8044E

TH/

Y

MTR

Y

TR

 

 

 

RR

ZONE 2

LOW VOLTAGE

THERMOSTAT

ZONE 2

24VAC ZONE VALVE

Taco 550

1

MTR

32

6ZONE RELAY

5

4DHW LIMIT

3CONTROL

2/N T

1/H T

40 VA TRANSFORMER

CONTINUED ON NEXT PAGE ►

AquaSmart Boiler Control Manual

23

Page 23