Final Checklist

Before Leaving the Installation Site, Verify:

□All wiring has been done correctly in a workmanlike way, is secure and meets all applicable codes.

□AquaSmart control temperature settings, differentials and optional functions are correctly set.

□The control program is functioning properly by observing at least one complete cycle.

□At shutdown, the temperature and pressure level match the recommended settings.

□The pressure relief valve operation and boiler water feed system works properly by bleeding some water and observing the refill cycle.

□The low water cutoff operation by lowering the water level until it shuts the burner off.

□The boiler passages and vent system are clear of obstructions and operating to the appliance manufacturer’s specifications and all required clearance dimensions to combustible materials are met.

□With combustion test instruments the burner is set to manufacturer’s specifications.

□After the system has run through a complete cycle, that all fittings are free of leaks.

□A record has been made of all service work and all temperature control settings and optional functions. Attach a label or tag to the boiler for future reference.

□The AquaSmart Installation Manual is left at a suitable location near the boiler for future reference and the equipment owner is informed of this.

□The control door is attached and securely closed.

Service

During Annual Maintenance or More Frequent Service Intervals, Verify the below items.

Note: The 7600 control has no serviceable internal parts. DO NOT attempt to repair a malfunctioning control.

□The control is clean and all vents are free of dust, lint or foreign material.

□All wiring is tight, terminals are free from corrosion and insulation is intact.

□There is no physical damage to the case or display.

□There is no evidence of water damage on the control or terminals.

□The control is securely mounted to the well or other mounting support.

□The sensor is in its place, with no evidence of tampering.

□The sensor lead on remote mounted units is in good condition and securely anchored in the immersion well with the strain relief.

□The control temperatures, differentials and optional functions are set correctly and working to established specifications. Consult the service tag or label on the boiler.

□A record of service and any adjustments are made to the service label or tag.

□The control door is attached and securely closed.

Accessories

AquaSmart Remote Mount Unit Pack • 7600RMU

Includes:

○Cable Assembly with Coupler

○Mounting Template

○Self-drilling Screws (Qty:3)

○Cable Ty-wrap

AquaSmart Temperature Sensor Unit Pack • 7600TSU

Includes:

○Temperature Sensor

○Cable Ty-wrap

○Joint Compound

○Installation Instructions

AquaSmart 2-in-1 Sensor Unit Pack • 76002N1S01U

Includes:

○2-in-1 Sensor

○36” Ground Wire

○Pipe Clamp for grounding

○Installation Instructions

AquaSmart Boiler Control Manual

33

Page 33
Image 33
Beckett 7600 manual Final Checklist, Service, Accessories