BENDIX TU-FLO 400-500-1000 AIR COMPRESSOR manual Releases air Compressor builds too much air

Models: TU-FLO 400-500-1000 AIR COMPRESSOR

1 40
Download 40 pages 29.3 Kb
Page 26
Image 26

Symptom:

What it may indicate:

What you should do:

 

 

 

10.0Air charging (a)Governor malfunction*. system doesn’t

build air.(b) Restricted discharge line.

(c)Air dryer heater malfunction: exhaust port frozen open.

(d)Compressor malfunction.

*Note: For the Bendix® DuraFlo596 air compressor, not only the governor, but also the SV-1synchro valve used would need to be tested. See Bulletin TCH-001-048.

ðGo to Test 4 on page 30.

ðSee 9.0(f).

ðReplace air dryer heater.

ðReplace the compressor only after making certain the preceding conditions do not exist.

11.0Compressor (a)Restricted discharge line. safety valve

releases air (Compressor builds too much air).

Damaged discharge line shown.

ðIf discharge line is restricted:

ðBy more than 1/16" carbon build up, replace the discharge line (see Table A, column 2, on page 18 for recommended size) and go to Test 3 on page 29.

ðBy other restrictions (e.g. kinks). Replace the discharge line. See Table A, column 2, on page 18 for recommended size.

ðThe discharge line must maintain a constant slope down from the compressor to the air dryer inlet fitting to avoid low points where ice may form and block the flow. If, instead, ice blockages occur at the air dryer inlet, insulation may be added here, or if the inlet fitting is a typical 90 degree fitting, it may be changed to a straight or 45 degree fitting. For more information on how to help prevent discharge line freeze-ups, see Bendix Bulletins TCH- 08-21 and TCH-08-22 (Appendix B). Shorter discharge line lengths or insulation may be required in cold climates.

(b)Downstream air brake system check valves or lines may be blocked or damaged.

(c) Air dryer lines incorrectly installed.

ðInspect air lines and verify check valves are operating properly.

ðEnsure discharge line is installed into the inlet of the air dryer and delivery is routed to the service reservoir.

(d)Compressor safety valve malfunction.

(e)Compressor unloader mechanism malfunction.

(f) Governor malfunction.

ðVerify relief pressure is 250 psi. Replace if defective.

ðGo to Test 6 on page 30.

ðGo to Test 4 on page 30.

26

Page 26
Image 26