6.Refit the filter case by aligning and inserting it into the projector slot.
7.Press the case back until it clicks into place.
8.Turn the projector back on.
If the case is not correctly seated in place, the projector will display an
The message will display 3 times for a
WARNING
Check the Air Filter
The air filter is not installed well. Please reinstall again.
OK
Then a second message as pictured to the right displays to warn of shutdown in 1 minute.
You can
Power Off
The air filter is not installed well. Please reinstall again.
Otherwise, the projector will be turned off in 60 seconds.
Replacing the filter sponge
If you find the dirt is hard to remove from the filter sponge or the sponge is broken, replace it.
1.Carefully peel the filter sponge away from the filter case.
See that there are small plastic pins along the edges to position and retain the sponge into place. Lift the sponge up off these pins taking care to prevent them from breaking off.
2.Attach the supplied new filter sponge to the filter case.
Make sure that the tiny holes securely fit onto the case's pins.
Plastic pins