Step 9. Resetting the lamp counter
Do not reset if the lamp is not replaced as this could cause damage.
i. Press and hold the Exit 5 button on the projector for 5 seconds to display the total used lamp time.
ii.Press Auto on the projector or on the remote control to reset the lamp hour to “0”.
iii.Wait about 5 seconds to let the OSD disappear.
Temperature information
When the Temperature warning light is on, it is warning you of the following possible problems:
1.The internal temperature is too high.
2.The fans are not working.
Turn the projector off and contact qualified service personnel for further help.
For more detailed information, please refer to "Indicators" on page 34.
Indicators
Illustration
1.Blank
2. : Light flashing
3. : Light ON
4.O : Orange light
5.R : Red light
6.G : Green light
Light |
| Status & Description | |
|
|
| |
Power | Temp | Lamp |
|
|
|
|
|
Power events |
|
| |
|
|
|
|
(1)The projector needs 110 seconds to cool down as it was abnormally shut down without the normal cooling down
|
|
| - | - | process. Or |
O |
| ||||
| |||||
|
|
(2)The projector needs to cool for 110 seconds after the power is turned off.
|
| |
O | - | - |
The Power indicator light is flashing during powering up.
G |
| - | - | ||
| |||||
|
|
|
|
|
|
|
| The projector is under normal operation. |
G | - | - |
34 Maintenance