5

Light Pixel

Gray 6

No light pixels visible on Gray 6

 

 

 

 

6

Minor Blemishes

White or Black

Total of Dark and Light Blemishes

 

 

 

4

 

 

 

(See Test 4 , 5)

 

 

 

 

7

Unstable Pixel

Red Ramp

No unstable pixels

 

 

Screen(or any

 

 

 

other

 

 

 

 

 

 

TABLE 1. Image Quality Specification

Notes:

1.The acceptance basis for all cosmetic DMD defects will be the projected image tests referenced in Table 1.

2.Projected blemish numbers include the shadow of the artifact in addititon to the artifact itself.(Count=4)

4.The projected image shall not contain any blemish more than 15 cm long, measured on a 1.32m diagonal screen.

20

Page 21
Image 21
BenQ PE8700 service manual Image Quality Specification