3 The variance of color coordinate via R,G,B gains:

 

x

Y

R

X

-

G

-

y

B

X

y

4.Adjust 6500K temperature color by changing Gamma-Rgain, Ggain, and Bgain.

5.Open Factory OSD and set the factory default value :

user>setup>white

C0

C1(5400k

C2(6500k

C3(7500k

Gamma-Rgain

512

512

512

512

Gamma-Ggain

512

412

467

479

Gamma-Bgain

512

398

452

490

User the lux meter and adjust Gamma-Rgain, Gamma-Ggain, & Gamma-Bgain to meet the spec.

6.Press “Save Graphics Color Temp” to save current setting into memory.

7.Select “Save Setting” at “Factory OSD>Factory>”.

8.Change pattern to 10% gray pattern and measure the color temp. If 6500K color spec is not met, repeat all procedures in C and D.

9.Follow step 1 to 8 to adjust 5400K, 7500K color temperature.

10.For auto-alignment, use Command Y31/Y32/Y33 to save 5400K/6500K/7500K temperature

11.For auto alignment, use Command to reset Temp4 color temp to 6500K

4.YPBPR Color Alignment

(A) YPbPr Component: Equipment:

-Pattern generator (VG-828)

-Lux meter ( CL-100)

OSD Default value used for YPBPR color alignment

Item

Value

Item

Value

USER>Picture>

 

 

 

Brightness

30

 

 

 

 

 

 

Contrast

17

 

 

Color

30

 

 

 

 

 

 

Tint

15

Factory>HD ADJ>YPbPr>

 

 

 

 

 

Sharpness

3

Brightness

60

32

Page 33
Image 33