BenQ PE8700 service manual Definition, Test Order

Models: PE8700

1 97
Download 97 pages 7.19 Kb
Page 15
Image 15

3.Definition

3.1 Failure Criteria:

The product is expected to perform to its full potential without loss of function, performance, critical parametric changes, and other undesirable anomalies, over the applied boundaries of this specification. The following product failure are not allowed within the boundaries defined in this specification:

1.Failure including permanent damage, critical parametic changes (optical performance defined in Appendix A), and latent defects.

2.Failure requiring operator intervention.

3.Failure violating external laws, regulatory agency standards, and government directives.

4.Failure resulting in a safety, potential safety, issue.

3.2EUT: Equipment under Test

3.3Q: Peak Acceleration Response divided by acceleration input peak

4.Test Order

Atmospherics, Dynamic, and Safety test sets require separate units and can be processed in parallel. EUT testing shall be performed serially within each set.

Set 1 (3 units)

Set 2 (3 units)

Set 3

Dynamics:

Atmospherics:

Safety/EMC:

Package Drop

Temperature/Humidity, Operating

EFT

Package Vibration

Temperature/Humidity,

ESD

 

Non-operating

 

Shock

Altitude, Operating

EMI-Radiated

Bench Drop

Aging

EMI-Conducted

 

 

EMI-Susceptibility