And the length of ACK must be 12, and format is

Z0_072+0025Z

Byte 1: Always ‘Z’

Byte 2: ACK

Byte 3: Always ‘_’

Byte 4~6: function code

Byte 7: sign byte, ‘+’ or ‘-‘

Byte 8~11: the current value after writing

Byte 12: Always ‘Z’

And ‘ACK’ value is

0:Right command and function

1:Illegal Format

2:Illegal Function

3:Illegal Action,

4:Illegal Adjusted Situation,

5.Written value is over up limit,

6.Written value is over down limit

If the ACK is 0, 5, 6, program will deal this command. If ACK = 5, program writes the legal maximum value to the setting. If ACK = 6, writes the legal minimum value to the setting.