BenQ PE8700 service manual Appendix B Design Verification Test Procedure, Purpose, Test Summary

Models: PE8700

1 97
Download 97 pages 7.19 Kb
Page 14
Image 14

Appendix B Design Verification Test Procedure

1.Purpose

This standard establishes the environmental specification for projector related products, which defines the level of product performance and reliability in the field. It is not necessary the intent of these specification to simulate a typical user environment, but rather to provide for a level of product robustness that when applied over a wide range of manufacturing variability and environmental usage conditions.

2.Test Summary

Dynamic Testing

Specification

 

 

Package Drop

76cm, 1 drop per orientation, all 6 primary surfaces, plus a selected

 

corners, and three selected edges, total of 10 drops

 

 

Package Vibration

Random , 0.01g2/Hz, 5~100Hz, all primary axis, 20 min per orientation,

 

total of 60min

 

Sine, 0.5g, 5~200Hz, 1 octave/min, 15 min dwell on each resonant

 

frequency, all primary axis, one sweep (30min minimum) per orientation,

 

total of 90+min

 

 

Shock, non-operating

50g, 20ms half-sine, all primary axis, 1 shock per orientation, total of 3

 

shocks

 

 

Security Lock

150N break away force

 

 

Fragility

Shock, 50g, 20ms half-sine, all primary axis, 1 shock per orientation, total

 

of 3 shocks

 

Accelerate Life Test (operating), 65 oC, 72hr

 

Thermal shock(bare board), -65~125oC, 48hr

 

Input Voltage, 90~264V

 

Input RGB signal, 0.7V±0.1

 

 

Atmospherics

 

 

 

Temperature/Humidity,

10~35oC/10~80RH, 48hr

operating

 

 

 

Temperature/Humidity,

-10~70oC/10~80RH, 48hr

non-operating

 

 

 

Altitude, operation

0~6000ft@30oC, 4hr

Safety/EMC

 

 

 

UL/cUL

 

 

 

TUV Rheinland

 

 

 

Fcc/CE/C-Tick

 

 

 

13

Page 14
Image 14
BenQ PE8700 service manual Appendix B Design Verification Test Procedure, Purpose, Test Summary