Image 13
Manual/Hose Cleaning

Troubleshooting

Manual/Hose Cleaning

Cleaner will not run

Possible Causes

Remedies

1.

Power cord not plugged in.

1.

Check electrical plug.

2.

Blown fuse/tripped breaker.

2.

Replace household fuse or

 

 

 

reset breaker.

3.

Hose not removed from receiver.

3.

Remove Hose.

Unusual or Odd Noise

Possible Causes

Remedies

1. Clean/Solution tank is out of fluid.

1. Fill Clean Solution Tank.

Reduced or No Spray

Possible Causes

Remedies

1.

Spray Tip clogged on Tough Stain Brush.

1.

Clean Spray Tip.

2.

Clean/Solution tank is out of fluid.

2.

Fill Clean/Solution Tank.

3.

Clean/Solution tank is not inserted

3.

Gently press the Clean/Solution

 

into the unit securely.

 

Tank Until you see “bubbles”

 

 

 

coming from the base of the tank.

No Suction

Possible Causes

Remedies

1.Tank is full.

2.Dirty/Collection tank latch is not down.

3.Black Valve on the Dirty/Collection Tank is missing.

1.Empty tank.

2.Push latch down, securely into place.

3.Replace Black Valve into Dirty/ Collection tank.

Thank you for selecting a BISSELL product.

Please do not return this product to the store.

For any question or concern, BISSELL is happy to be of service.