Troubleshooting
Diagnostic Codes: ET0100A and ET1000A
The
When the appliance powers up, all LEDs illuminate. The Alarm LED illuminates briefly and the diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning. As the ETEP cycles through its
If the ETEP fails to boot properly the diagnostic code display indicates the number of the last test that completed successfully, and a message describing the failure is displayed on the terminal. In addition, the Alarm light illuminates if diagnostic tests
Table 27 | ET0100A/ET1000A | |
|
|
|
Code |
| Description |
88 |
| |
01 |
| Bootflash CRC test. |
02 |
| DRAM test #1. |
03 |
| Initialize IO devices. DRAM test #2. |
04 |
| Initialize compact flash. |
05 |
| Complete bootloader initialization. |
06 |
| Download operating system. |
07 |
| Start operating system, IPSec dataplane code, and management |
|
| and control software. |
00 |
| Up and operational. |
|
|
|
After the ETEP boots up, the diagnostic display reflects the operational state of the appliance.
.
Table 28 | ET0100A/ET1000A Operational Codes | |
|
|
|
Code |
| Description |
00 |
| Up and operational. |
rb |
| The ETEP is in a reboot required state. |
AL |
| An alarm condition or error condition has been reported. |
dL |
| The ETEP is downloading new software. |
– – |
| The ETEP is in a shutdown state. |
|
|
|
64 | ETEP Installation Guide |