Multiple video head connections

Two or more ServSwitch CX Uno IP units can be connected together so that they operate in a synchronized manner. Synchronized operation is useful for applications that require multiple video signals to be switched together. This type of operation is usually required where each computer is fitted with multiple video cards or video cards with multiple video heads. Whenever an ServSwitch CX Uno IP channel is switched, it sends an RS232 command out on its serial interface (marked OPTIONS on the rear panel). An ServSwitch CX Uno IP will switch its channel if it receives the same command on its serial interface. Consequently, by linking the serial interfaces, a master unit may be made to automatically switch one or more slave units as shown in the diagram.

LOCAL LOCAL

USER USER

®

724-746-5500

®

724-746-5500

SAM SAM

HOST

COMPUTER

Serial synchronization cable

Slave ServSwitch CX Uno IP

 

16

15

14

13

8

7

6

5

ONLY

 

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOORUSE

5V

12

11

10

9

4

3

2

1

2.0A

 

 

 

COMPUTER CONNECTIONS

 

 

COMPUTER CONNECTIONS

 

 

®



Note: You must ensure that all ServSwitch CX Uno IP units have their Options serial ports set to ‘Sync Units’ and that their baud rates are identical. These settings can be made either via the local or global user configuration menus.

It should be noted that the synchronization cable deliberately does not have the transmit pin of the Slave End connector linked to the receive pin of the Master End connector. To do so would cause the Slave unit to be able to switch the Master unit. This would setup an endless cyclical switching sequence that would prevent the ServSwitch CX Uno IP devices from operating correctly. For more details about the serial synchronization cables, see Appendix 7.

 

16

15

14

13

8

7

6

5

ONLY

 

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOORUSE

5V

12

11

10

9

4

3

2

1

2.0A

 

 

 

COMPUTER CONNECTIONS

 

 

COMPUTER CONNECTIONS

 

 

Master ServSwitch CX Uno IP

 

Notes

Slave monitor

Master monitor

It is recommended that the

 

 

 

 

 

 

 

 

second SAM in each pair is a

SAM SAM

SAM SAM

 

 

USB-type and that it is plugged

 

 

 

 

 

 

to a vacant USB port on the host

 

 

 

 

computer to derive its power.

 

 

Pairs of SAMs can be strapped back-to-back with cable ties to create a tidy installation.

Computers fitted with dual video heads

 



17

Page 18
Image 18
Black Box servswitch cx uno ip manual Multiple video head connections, It is recommended that Second SAM in each pair is a