Black Box SW590A-R2, SW591C manual Code Operated Switch, Ascii

Models: SW591C SW590A-R2

1 23
Download 23 pages 24.54 Kb
Page 10
Image 10
ASCII

CODE OPERATED SWITCH II

3.6.2SETTING THE ARMING CHARACTER WITH SWG

Switch Bank SWG supplies a portion of the control-code sequence, the sequence that activates the Switch. The arming character, the ASCII code that alerts the COS-II to an upcoming switch action, is set with SWG. The settings are given in the chart below. For a more detailed explanation of control codes, see Section 4.2. A note on abbreviations: LSB stands for least significant bit, MSB for most significant bit.

ARMING CHARACTER SWITCH POSITIONS

 

 

 

 

 

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

MSB

ASCII

CTRL

HEX

DECIMAL

1

2

3

4

5

6

7

8

NUL

@

00

0

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

SOH

A

01

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

STX

B

02

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

ETX

C

03

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

EOT

D

04

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ENQ

E

05

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

ACK

F

06

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

BEL

G

07

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

BS

H

08

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

HT

I

09

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

LF

J

0A

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

VT

K

0B

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

FF

L

0C

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

CR

M

0D

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

SO

N

0E

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

SI

O

0F

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

DLE

P

10

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

DC1

Q

11

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

DC2

R

12

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

DC3

S

13

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

DC4

T

14

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

NAK

U

15

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

SYN

V

16

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

ETB

W

17

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

CAN

X

18

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

EM

Y

19

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

SUB

Z

1A

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

ESC

[

1B

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

FS

\

1C

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

GS

]

1D

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

RS

^

1E

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

US

_

1F

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

SP

 

20

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

!

 

21

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

"

 

22

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

#

 

23

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

$

 

24

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

%

 

25

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

&

 

26

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

10

Page 10
Image 10