3.4 Bank Assignments

CODE OPERATED SWITCH II

In addition, there are some system characteristics that are set with the eighth DIP switch of the individual port switch banks. Sections 3.6 and 3.7 explain these functions in depth.

3.4 Bank Assignments

The individual port switch banks are assigned as follows:

Bank Label

Port

SWA

Master Device Port

SWB

0

SWC

1

SWD

2

SWE

3

The Four-Port Expansion Board provides these additional banks:

Bank Label

Port

SWH

4

SWI

5

SWJ

6

SWK

7

3.5Configuring Ports with the Individual Port Switch Banks

To set the switch banks, use a small screwdriver or other small object with a clean edge or point. The individual port switch banks are identical in function, and the set of charts provided on the following pages applies to all of them.

3.5.1PORT SPEED (SWITCHES 1, 2, AND 3)

Speed

 

Set Switches

 

 

 

1

2

3

 

110 bps

ON

ON

ON

300 bps

OFF

ON

ON

600 bps

ON

OFF

ON

1200 bps

OFF

OFF

ON

2400 bps

ON

ON

OFF

4800 bps

OFF

ON

OFF

9600 bps

ON

OFF

OFF

19200 bps

OFF

OFF

OFF

3.5.2PARITY (SWITCHES 4 AND 5)

Parity

Set Switch

 

4

5

Even

OFF

ON

Odd

ON

OFF

None

OFF

OFF

3.5.3WORD SIZE (SWITCH 6)

Size

Set Switch 6

7 bits per word

OFF

8 bits per word

ON

3.5.4FLOW CONTROL (SWITCH 7)

Flow Control

Set Switch 7

Hardware (DTR/CTS)

ON

Software (X-ON/X-OFF)

OFF

3.6Setting Global Characteristics with the System Switch Banks

Refer to the explanations and the charts below to set the system switch banks SWF and SWG.

3.6.1FUNCTIONS OF SWITCH BANK SWF

Responsibility for the Link Command

When the COS II receives a control code sequence from the proper device, it will establish a communications link between the master port and one of the slave ports. If it then receives the lockout character—a character with a value of 38 in hexadecimal—it will ignore the remaining unlinked subordinate ports. For more information on links and lockouts, see Sections 4.2 and 4.3.

You can set the Switch to accept the command to link from only the master port, only a slave port, or from either the master or a slave port. Switches SWF 1 and SWF 2 designate the origin of the link.

 

Set SWF

 

Origin of Command

1

2

master

ON

ON

slave

OFF

ON

either master or slave

ON or OFF

OFF

NOTE: If the slave ports are set up for hardware flow control, or if DTR/CTS pass-through is enabled, you should set the Switch to accept a link command from the master port only.