Black Box V5.1 user manual Black Box Networks PICO systems, TP Link, Rx Ok, Level, Saturation

Models: V5.1

1 27
Download 27 pages 63.6 Kb
Page 19
Image 19
TP Link

Black Box Networks PICO systems

Pico Manual v5.1

Fiber optical link between the two heads.

TP Link

Copper side link between the head and the Network equipment.

RX OK

There is enough light to start communicate through the link.

Level 1

25% of the total (acceptable by the receiver) incoming power

Level 2

50% of the total (acceptable by the receiver) incoming power

Level 3

75% of the total (acceptable by the receiver) incoming power

Saturation

Overload (Overloading can cause stop in the communication, and permanently it can damage the receiver)

7.If the installation distance is shorter than 50 meters in that case

realignment is required which can be done with the device on the picture.

7.1release the screws

7.2Pull the regulation nut perfectly to the front and fix it with the screws! Please note that this operation should be done extra carefully because it can

move the transmitter out of the alignment. It must be totally on the front!