SERVICE | INFRARED CHEESE MELTER |
ADJUSTMENT OF CHEESE MELTER BURNERS
The
ADJUSTMENT OF GAS PRESSURE REGULATOR
The pressure regulator is located in the
1.Turn Cheese Melter control knob to OFF.
2.Attach a
3.Turn the Cheese Melter control knob to HIGH and, with the burners lit, check the manifold pressure. The pressure should be 4" W.C. (for natural gas) or 10" W.C. (for propane gas).
4.If necessary, adjust the pressure by unscrewing the top of the pressure regulator (use a screwdriver) to expose the adjustment screw underneath. Rotating the adjustment screw clockwise increases the manifold pressure.
5.After the pressure has been adjusted, turn the Cheese Melter control knob to OFF, replace the top of the pressure regulator, and disconnect the
PAGE 20 OF 28 | INSTALLATION AND OPERATION MANUAL 1186533 REV 1 (02/06) |