| TROUBLESHOOTING SUGGESTIONS |
|
|
|
| |||||
|
| SYMPTOM |
| POSSIBLE CAUSE | SUGGESTED REMEDY |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water won’t heat |
| Brewer unplugged or circuit | Check power supply cord |
|
| ||||
|
|
|
|
| breaker tripped | Check / reset circuit breaker |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Temperature adjusted too low | Turn on and set for desired |
|
| |||
|
|
|
|
| or set to OFF | temperature. See page 15 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allow to cool (1012, 1040 or |
|
| ||||
|
|
|
|
|
|
|
| 1072), or allow to cool and |
|
| |
|
|
|
|
|
|
|
| reset |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Damaged internal component or | Examine wiring & connectors, |
|
| |||
|
|
|
|
| wiring | controller, power board and |
|
| |||
|
|
|
|
|
|
|
| heating element |
|
| |
|
|
|
|
|
|
|
| Repair/replace as needed |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Coffee level too high or low |
| Timer out of adjustment | Adjust controller. See page 16 |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Brew chamber overflows |
| Too many filter papers or wrong | Use one (1) genuine Bloomfield |
|
| ||||
|
|
|
|
| filter paper | filter per brew |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Brew chamber dispense hole | Thoroughly clean brew chamber |
|
| |||
|
|
|
|
| plugged |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Sprays water from brew head |
| Spray gasket improperly | Check/reinstall gasket on |
|
| ||||
|
|
|
|
| installed | INSIDE of brew head |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| No brew while faucet flows OK |
| Spray disk plugged | Clean spray disk |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Damaged internal component | Check keypad, controller, power |
|
| |||
|
|
|
|
| or wiring | board & solenoid |
|
| |||
|
|
|
|
|
|
|
| Repair, replace as needed |
| 642 | |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| 75872 |
|
| No brew plus no flow from hot |
| Water supply OFF | Turn water supply ON |
| |||||
|
|
|
|
| |||||||
|
| water faucet |
|
|
|
|
|
|
| Owners | |
| Solenoid screen plugged | Clean solenoid screen |
| ||||||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| No flow from hot water faucet |
| Water line strainer (if used) | Clean strainer |
| ManualE.B | ||||
|
|
| Water filter (if used) plugged | Replace filter element |
| ||||||
|
|
|
|
| plugged |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| .C. |
|
|
|
|
| Faucet valve turned OFF | Turn faucet valve ON |
| ||||
|
|
|
|
|
| Airpot | |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Faucet plugged | Disassemble faucet, clean |
| ||||
|
|
|
|
|
| /Thermal | |||||
|
|
|
|
|
|
|
|
|
|
| |
|
| Poor coffee quality |
| Keep brewer, airpots and servers clean. Install a taste and odor |
| ||||||
|
|
|
|
| |||||||
|
|
|
|
| filter in water supply, and replace cartridges regularly. |
|
| ||||
|
|
|
|
| Use a quality coffee with a consistent roast. Use proper grind and |
|
| ||||
|
|
|
|
| amount of coffee per brew. |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|