Bloomfield 1086, 1082, 1080 Error Detection, Electric Shock Hazard, What To Check, Description

Models: 1088 1082XL 1080 1082 1086

1 30
Download 30 pages 36.82 Kb
Page 15
Image 15
ERROR DETECTION

This brewer is designed to perform a continuous internal diagnosis, and to signal faults by flashing all the lights. In fault mode, warmers, heating element and water fill solenoid are turned “off”, and most keypad functions are disabled.

Error detection (all lights flashing) will occur under two conditions:

Anytime a temperature in excess of 214ºF is detected.

Temperature does not change by at least 2ºF within 4 minutes of tank heater being energized (HEAT light on).

To reset the brewer after the fault has been corrected, press and hold the CANCEL key for 3 seconds, or disconnect the brewer from electrical power for three seconds.

ERROR DETECTION

CAUTION

ELECTRIC SHOCK

HAZARD

Live electrical circuits may be exposed while performing these procedures.

These procedures are to be performed by qualified technical personnel only.

642 75872 Owners Manual E.B.C. Airpot /Thermal

 

WHAT TO CHECK

DESCRIPTION

CORRECTIVE ACTION

 

 

 

 

 

Has the water tank

On initial startup, an attempt to heat a

Tank must be properly filled as

 

been properly filled?

dry tank will be detected as too high a

detailed on page 6.

 

 

temperature or insufficient temp rise, or

Check hi-limit (see below)

 

 

will trip the high limit.

 

 

 

 

 

 

Has hi-limit safety

Brewer may have been started without

Access hi-limit by removing front

 

thermostat tripped

water in the tank, or the temp control

panel. Hi-limit is on the left side of

 

off?

thermostat may require adjustment.

the tank. Use an insulated tool to

 

 

 

push the red button in until it “clicks”

 

 

 

and stays. Reset per above.

 

 

 

 

 

Check control board

Brewer will go into error mode

Reset by holding the CANCEL key for

 

and temp probe.

immediately if either the control board

3 seconds. If lights continue to flash:

 

 

or temp probe is defective.

Disconnect temp probe from control

 

 

Temp probe electrical resistance is

board.

 

 

approximately 30Kat room temp, and

a. If lights continue to flash, unplug

 

 

brewer and replace control board.

 

 

2K at boiling. Replace temp probe if

b. If lights stop flashing, unplug

 

 

Ω.

 

 

less than 1K

brewer and replace temp probe.

 

 

 

 

 

 

 

 

Check power board

Brewer will go into error mode 4 minutes

Reset by holding the CANCEL key

 

and heating element..

after energizing the heating element if

for 3 seconds. If lights resume

 

 

insufficient heat rise is detected. The

flashing after 4 minutes:

 

 

heating element is energized by an

Check the voltage across the heating

 

 

electronic power board, and protected

element terminals:

 

 

by the hi-limit safety.

a. If no voltage is present, unplug

 

 

Heating element should receive full line

brewer and replace power board.

 

 

voltage (i.e. 120V, 208V or 240V).

b. If proper voltage is present,

 

 

Be sure the hi-limit safety is reset.

unplug brewer and replace tank

 

 

 

heating element.

 

 

 

 

 

Is the brew

The brewer may occasionally go into

See page 15 for temperature

 

temperature properly

error mode if the brew temperature is

adjustment procedure.

 

adjusted?

set too high.

 

 

 

 

 