Bloomfield 1080, 1086, 1082 SERVICING INSTRUCTIONS continued, Temp. ºf, Temperature Adjustment

Models: 1088 1082XL 1080 1082 1086

1 30
Download 30 pages 36.82 Kb
Page 17
Image 17
SERVICING INSTRUCTIONS (continued)

SERVICING INSTRUCTIONS (continued)

TEMPERATURE ADJUSTMENT

Unplug power cord or turn circuit breaker OFF. Remove top panel. Remove button plug from front panel.

CAUTION

Electric Shock

Hazard

These procedures involve exposed electrical circuits. These procedures are to be performed by qualified technical personnel only.

Fig. 13 Checking and Adjusting Brew Temperature

Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power. Place empty container under brew chamber. Energize brewer and pour one decanter (64 oz.) of cold water into pour-over opening. When HEAT light goes out, read the temperature displayed on thermometer.

Adjust WATER TEMP dial on controller; clockwise increases temperature. Refer to Table 1 below for proper brewing temperature based on altitude.

NOTE: Optimum brewing temperature is 195ºF to 205ºF (90ºC to 96ºC).

Maximum temperature setting should be no more than 205ºF (96ºC).

Manual E.B.C. Airpot /Thermal

TEMP. (ºF)

210

205

200

195

190

0

 

0

 

0

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POINT OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDEAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREWING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

0

 

 

0

 

 

0

 

0

 

0

 

0

 

0

 

0

 

0

 

0

 

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

 

0

 

 

0

 

 

0

0

0

 

 

 

 

 

 

 

0

 

 

0

 

 

5

 

 

0

 

,5

 

 

0

 

0

0

0

0

 

0

 

0

 

 

 

,

 

 

 

,

 

 

 

,

 

 

 

,0

 

 

,5

 

,0

 

,5

 

,0

 

,5

 

 

,

 

 

,5

 

 

 

 

1

 

 

1

 

2

 

 

2

 

3

 

 

3

 

4

 

4

 

5

 

5

 

6

 

 

6

 

 

 

 

ELEVATION (feet above seal level)

 

 

 

 

 

 

IMPORTANT:

An electronic temperature controller will maintain temperature within ±2ºF.

To prevent boiling water in the brewer, controller should be adjusted to a maximum temperature equal to the local boiling temperature minus 2ºF, or 205ºF, whichever is less.

642 75872 Owners

Table 1 Boiling Temperature by Altitude

Upon completion, remove thermometer and reinstall vent tube.