508 p/n 304456 OpManual WV-2H Series Ventless Combo Cook Center

UNPACKING & INSPECTION

Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure.

Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.

Read and understand all labels and diagrams attached to the appliance.

Carefully account for all components and accessories before discarding packing materials. Store these components in or near the appliance for later use. These items must be installed before operating the appliance.

1 ea. FIRE SUPPRESSION AGENT (ANSULEX® Low pH, 1.5 GAL.) See Material Safety Data Sheet, page 28.

1 ea. FIRE SUPPRESSION MEDIA TANK

1 ea. FIRE SUPPRESSION TANK CHARGING CARTRIDGE

1 ea. GREASE BAFFLE

1 ea. FILTER PACK ASSEMBLY

1 ea. PRE-FILTER HOLDER with PRE-FILTER 1 ea. GREASE DRIP TRAY

1 ea. GREASE DRAWER ASSY FOR GRIDDLE

2 ea. 6” SIDE SPACERS

1 ea. LITERATURE PACKAGE Additionally:

2 ea. DRAWER PANS (if unit has optional drawer warmers)

2 ea. HUMITROL RACKS (if ordered with warmer drawers)

SETUP

Setup the appliance only on a firm level surface. Non-combustible material is recommended.

Refer to the Installation Instruction Sheet for required clearances. Maintain required clearances between the appliance and adjacent combustible surfaces. Verify 6” left and right side clearances to combustible construction. This appliance requires a minimum of 8 ft (96”) (floor to overhead) to allow for adequate exhaust.

IMPORTANT: Provided 6" side spacers (item 58) must be installed on the appliance.

Factory installed side shields (item 57) are required.

Verify that the VENTILATOR HOOD ASSEMBLY is properly and securely assembled to the cooking appliance before beginning the installation procedure.

If a remote manual pull station is to be installed, replace the rear casters with legs.

Level the unit after it is in its final position. Using a spirit level, verify that the unit is level front-to-back and side-to-side.

INSTALLATION

NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.

Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.

WARNING:

RISK OF

INJURY

Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical codes. Failure can result in personal injury and property damage.

WARNING:

FIRE HAZARD

Avoid storing flammable or combustible materials near the appliance.

9

Page 11
Image 11
Bloomfield WV-2HSGRWT, WV-2HFGRWT operation manual Unpacking & Inspection, Installation, Risk Injury, Setup

WV-2HFGRW, WV-2HFG, WV-2HSGRW, WV-2HFGRWT, WV-2HSGRWT specifications

Bloomfield WV-2HSG, WV-2HSGRWT, WV-2HSGRW, WV-2HFGRW, and WV-2HFGRWT are innovative technologies designed to enhance various sectors, particularly in the fields of heating, ventilation, and air conditioning (HVAC). These models are recognized for their efficiency, versatility, and advanced features, making them popular choices among homeowners and professionals alike.

One of the standout features of the Bloomfield WV-2HSG series is its energy efficiency. These units are designed to consume less energy while providing maximum output, helping users save on utility bills without sacrificing comfort. The incorporation of environmentally friendly refrigerants also aligns with modern sustainability goals, reducing the overall carbon footprint of these systems.

The WV-2HSG model is particularly noted for its superior heating capabilities, which are ideal for colder climates. Its cutting-edge heat exchange technology ensures rapid heating and consistent temperature regulation throughout the space. This model is equipped with a user-friendly control interface, allowing for easy adjustments and programming of heating cycles to suit different preferences and schedules.

In contrast, the WV-2HSGRWT and WV-2HSGRW models emphasize adaptability in various humidity and air quality conditions. These systems feature advanced humidity sensors that monitor indoor conditions and automatically adjust operations to maintain a comfortable atmosphere. This is especially beneficial for areas prone to high humidity levels, as it prevents mold growth and promotes healthier living environments.

The WV-2HFGRW and WV-2HFGRWT variants stand out with their innovative filtration systems, which capture airborne particles, allergens, and contaminants. These models integrate HEPA filters coupled with activated carbon layers, ensuring clean and pure air circulation within the home. This characteristic is particularly appealing to individuals with allergies or respiratory issues, as it enhances overall indoor air quality.

All models within this range come equipped with smart technology integrations, enabling remote operation through smartphones and smart home systems. This not only adds convenience for users but also allows for monitoring and managing energy consumption effectively. Together, these features position the Bloomfield WV-2HSG series as exemplary products in the HVAC industry, merging efficiency, functionality, and cutting-edge technology to meet the needs of modern consumers.