Bloomfield WV-2HFGRW, WV-2HSG Unpacking & Inspection, Installation, Risk Of Injury, Fire Hazard

Models: WV-2HFGRW WV-2HFG WV-2HSGRW WV-2HFGRWT WV-2HSGRWT WV-2HSG

1 32
Download 32 pages 40.88 Kb
Page 11
Image 11
UNPACKING & INSPECTION

508 p/n 304456 OpManual WV-2H Series Ventless Combo Cook Center

UNPACKING & INSPECTION

Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure.

Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.

Read and understand all labels and diagrams attached to the appliance.

Carefully account for all components and accessories before discarding packing materials. Store these components in or near the appliance for later use. These items must be installed before operating the appliance.

1 ea. FIRE SUPPRESSION AGENT (ANSULEX® Low pH, 1.5 GAL.) See Material Safety Data Sheet, page 28.

1 ea. FIRE SUPPRESSION MEDIA TANK

1 ea. FIRE SUPPRESSION TANK CHARGING CARTRIDGE

1 ea. GREASE BAFFLE

1 ea. FILTER PACK ASSEMBLY

1 ea. PRE-FILTER HOLDER with PRE-FILTER 1 ea. GREASE DRIP TRAY

1 ea. GREASE DRAWER ASSY FOR GRIDDLE

2 ea. 6” SIDE SPACERS

1 ea. LITERATURE PACKAGE Additionally:

2 ea. DRAWER PANS (if unit has optional drawer warmers)

2 ea. HUMITROL RACKS (if ordered with warmer drawers)

SETUP

Setup the appliance only on a firm level surface. Non-combustible material is recommended.

Refer to the Installation Instruction Sheet for required clearances. Maintain required clearances between the appliance and adjacent combustible surfaces. Verify 6” left and right side clearances to combustible construction. This appliance requires a minimum of 8 ft (96”) (floor to overhead) to allow for adequate exhaust.

IMPORTANT: Provided 6" side spacers (item 58) must be installed on the appliance.

Factory installed side shields (item 57) are required.

Verify that the VENTILATOR HOOD ASSEMBLY is properly and securely assembled to the cooking appliance before beginning the installation procedure.

If a remote manual pull station is to be installed, replace the rear casters with legs.

Level the unit after it is in its final position. Using a spirit level, verify that the unit is level front-to-back and side-to-side.

INSTALLATION

NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation.

Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.

WARNING:

INSTALLATION RISK OF

INJURY

Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical codes. Failure can result in personal injury and property damage.

WARNING:

 RISK OF FIRE HAZARD

Avoid storing flammable or combustible materials near the appliance.

9

Page 11
Image 11
Bloomfield WV-2HSGRWT, WV-2HFGRWT operation manual Unpacking & Inspection, Installation, Risk Of Injury, Fire Hazard