The keyboard can now be physically connected to
Keyboard User Function 15

LTC 8555 Series Instruction Manual Installation

EN 15

 

 

If using the LTC 8059 Master Control Software, while online, select the Command Script tab and enter the script for your connection type exactly as it appears in the table below:

Keyboard interface

 

connection type

Command Script

 

 

Direct to Console port

Begin @boot

(except LTC 8900)

SET-PORT-RS232 0 4 8 0 1 0

 

_SET_KBD_MODE 0 1

 

break

Direct to Printer port

Begin @boot

(except LTC 8900)

SET-PORT-RS232 4 4 8 0 1 0

 

_SET_KBD_MODE 4 1

 

break

 

 

Modem connected to

Begin @boot

Console port

SET-PORT-RS232 0 4 8 0 1 1

(except LTC 8900)

_SET_KBD_MODE 0 1

 

break

Modem connected to

Begin @boot

Printer port

SET-PORT-RS232 4 4 8 0 1 1

(except LTC 8900)

_SET_KBD_MODE 4 1

 

break

 

 

Direct to Controller port

Begin @boot

(LTC 8900 only)

SET-PORT-RS232 0 4 8 0 1 0

 

_SET_KBD_MODE 0 1

 

break

 

 

After the script has been entered, download the script into the Allegiant CPU. Reset the system by powering the CPU off/on, or by entering

on an operating keyboard. The specified port will begin to operate in the keyboard mode. The port will remain in the keyboard mode unless manually cancelled by entering Ctrl-C several times using Windows HyperTerminal program, operating at 9600 baud.

The keyboard can now be physically connected to

the Allegiant according to details shown in FIGURE 6. For modem connections, refer to the next section and FIGURE 7.

Once the keyboard is in communication with the Allegiant, camera and monitor numbers will appear in the LED displays.

Direct to Console port

Begin @boot

(LTC 8900 only)

SET-PORT-RS232 4 4 8 0 1 0

 

_SET_KBD_MODE 4 1

 

break

Modem connected to

Begin @boot

Controller port

SET-PORT-RS232 0 4 8 0 1 1

(LTC 8900 only)

_SET_KBD_MODE 0 1

 

break

Modem connected to

Begin @boot

Console port

SET-PORT-RS232 4 4 8 0 1 1

(LTC 8900 only)

_SET_KBD_MODE 4 1

 

break

 

CONSOLE port on Allegiant

 

system must be configured

Allegiant system main

for

RS-232 Keyboard mode

CPU bay

(refer to text for details)

 

 

 

 

 

User-supplied cable or other link

User-supplied female

 

suitable for

 

 

full duplex RS-232 transmissions

9-pin D connector.

 

 

at 9600 baud

 

 

3 m (10 ft) data/ power cable supplied with keyboard

Junction box and power adapter supplied with LTC 8557 kit

Console pin 2 (Rx) to Tx of link or directly to pin 3 of LTC 8557 box. Console pin 3 (Tx) to Rx of link or directly to pin 2 of LTC 8557 box.

Console pin 7 (Gnd) to Data Gnd of link or directly to pin 1 of LTC 8557 box.

Figure 6: Direct Connection to Allegiant’s Console/Printer Port

Bosch Security Systems 29 August 2003