Address

36 en InstallingAMC2 4W

Address

 

DIL Switches

 

 

 

1

2

 

3

4

none

 

OFF

OFF

 

OFF

OFF

1

 

ON

OFF

 

OFF

OFF

2

 

OFF

ON

 

OFF

OFF

3

 

ON

ON

 

OFF

OFF

4

 

OFF

OFF

 

ON

OFF

5

 

ON

OFF

 

ON

OFF

6

 

OFF

ON

 

ON

OFF

7

 

ON

ON

 

ON

OFF

8

 

OFF

OFF

 

OFF

ON

Table 5.1

Setting the RS-485 address with the DIL switch

 

 

 

 

 

 

 

Mode

 

DIL Switches

 

 

 

 

5

6

 

 

 

 

 

 

 

 

ON

 

SDEB

RS-232

 

 

 

OFF

 

BPA

RS-485

 

 

 

Table 5.2

Protocol and connection settings

 

 

5.7RS-232 Host Interface

The AMC2 4W offers an RS-232 serial interface to connect a host computer or serial modem.

CAUTION!

! Cable length between two RS-232 COM serial interfaces must not exceed 15 meters (45 ft).

F.01U.024.965 V.4 2006.09