![1. Door open:RS + RP](/images/new-backgrounds/49537/4953789x1.webp)
AMC2 4W | Installing en 45 |
Fig. 5.22 Location of the analog input connectors
The AMC2 4W can also detect the wiring conditions ‘short cir- cuit’ and ‘broken’ and initiate an alarm if the appropriate devices are connected.
1. Door open:RS + RP
2. Door closed:RS
3. Broken wire:RS + RP =
4. Short circuit:RS + RP = 0
The resistor values can vary and depend on the used lock system (wire resistance negligible).
The AMC2 4W package includes 2,2 kΩ resistors using for reserves for the RS and the RP resistor.
Fig. 5.23 Operating modes of a lock
using the analog input device
i | NOTE! |
A complete connection diagram of the analog input devices is | |
shown in Figure 7.8. |
Bosch Security Systems | Installation manual | F.01U.024.965 V.4 2006.09 |