Bosch Appliances APC-AMC2-4WUS, APC-AMC2-4WCF Door open RS + RP 2. Door closed RS

Models: APC-AMC2-4W APC-AMC2-4WUS APC-AMC2-4WCF

1 60
Download 60 pages 34.33 Kb
Page 45
Image 45
1. Door open:RS + RP

AMC2 4W

Installing en 45

Fig. 5.22 Location of the analog input connectors

The AMC2 4W can also detect the wiring conditions ‘short cir- cuit’ and ‘broken’ and initiate an alarm if the appropriate devices are connected.

1. Door open:RS + RP

2. Door closed:RS

3. Broken wire:RS + RP =

4. Short circuit:RS + RP = 0

The resistor values can vary and depend on the used lock system (wire resistance negligible).

The AMC2 4W package includes 2,2 kresistors using for reserves for the RS and the RP resistor.

Fig. 5.23 Operating modes of a lock

using the analog input device

i

NOTE!

A complete connection diagram of the analog input devices is

shown in Figure 7.8.

Bosch Security Systems

Installation manual

F.01U.024.965 V.4 2006.09

Page 45
Image 45
Bosch Appliances APC-AMC2-4WUS, APC-AMC2-4WCF installation manual Door open RS + RP 2. Door closed RS