6BASICDOME ADVANCED COMMANDS

To use Locked Commands, you must first unlock the BasicDome via OFF-90-ENTER. All locked settings, except FastAddress, can then be changed via ON-46-ENTER. Disallow these commands via ON-90-ENTER.

SETUP

GENERAL

PTZ

CAMERA

Commands

FastAddress

Display FastAddress

Auto Iris

Auto Focus

Gain Control

On-screen Display

On-screen Display Adjust

Sector Title Edit

Sector Blanking

Bypass All Blanking

Lock/Unlock Commands

Password

Factory Home Position

Restore Defaults

Left Limit

Right Limit

Inactivity

Preset Tour Period

AutoPivot

Select White Balance

Sharpness

Iris Adjust

Sync Mode

Adjust Line Lock Phase

Switch Polarity

Keystrokes

ON-999-ENTER

ON-998-ENTER

ON-997-ENTER

ON/OFF-3-ENTER

ON/OFF-4-ENTER

ON/OFF-43-ENTER

ON/OFF-60-ENTER

ON/OFF-61-ENTER

ON/OFF-63-ENTER

ON-86-ENTER

OFF-86-ENTER

ON/OFF-90-ENTER

SET-802-ENTER

SET-110-ENTER

ON-40-ENTER

SET-101-ENTER

SET-102-ENTER

ON/OFF-9-ENTER

ON/OFF-15-ENTER

ON/OFF-18-ENTER

ON/OFF-30-ENTER or ON/OFF-35-ENTER

ON/OFF-44-ENTER

ON/OFF-11-ENTER

ON/OFF-42-ENTER

ON/OFF-41-ENTER

ON-91-ENTER

Description

Sets/changes the dome address using the keyboard and on-screen menus. (for cameras not already configured).

Sets/changes the dome address using the keyboard and on-screen menus. (for all cameras, even those already configured).

Briefly displays all dome addresses.

Camera (iris) adjusts automatically/manually (On/Off) to light conditions.

Camera automatically/manually (On/Off) focuses.

Turns gain control to Automatic or Off. When in Automatic mode, the gain increases to compensate for darker scenes.

Turns On/Off the On-screen Display. When off, there is no On-screen feedback.

Changes the characters and position of the display. On-screen instructions are provided.

Edits the current Sector name. On-screen instructions are provided.

Masks video from being displayed in selected sectors.

Removes all viewing restrictions imposed by sector blanking but keeps their locations in memory. ON-86-ENTER reactivates all blanking.

Allows/Disallows Locked Commands to be accessed.

Sets or displays password. See AutoDome Security, SECTION 4 for details.

SET recalibrates camera and returns it to home position.

Restores Factory Defaults.

Sets the current position as the left limit of Auto Pan. Default is 0 degrees.

Sets the current position as the right limit of Auto Pan. Default is 359.9 degrees.

Selects the mode that the dome reverts to after a duration without operator activity. Default is OFF.

Increase/Decrease (On/Off) the time between Presets during Preset Tour.

Allows a subject to be followed while beneath the camera, without inverting the picture. Default is ON.

Adjusts camera color (white balance) for specific settings.

Picture (vertical aperture) sharpens/softens.

Edits the Auto Iris level.

Sets camera sync for external-line/internal-crystal (On/Off).

Changes the phase delay of the camera when in external line lock mode.

Switches the polarity of the Zoom, Focus, and Iris controls.