Electrical Preparation
ELECTRICAL PREPARATION
30"
(762mm)
21"
(533mm)
Figure 4
Dishwasher Electrical Rating
Volt s | Hert z | Amperes | W a tts | |
120 | 60 | 12 | 1, 450 | |
( max) | ||||
|
|
| ||
|
|
|
|
3" - 4" (76mm - 102mm)
3/8" - 1/2" (10mm - 13mm)
Figure 5
WARNING
Avoid Electrical Shock Hazard
Do not work on an energized circuit. Doing so could result in serious injury or death. Only qualified electricians should perform electrical work. Do not attempt any work on the dishwasher electric supply circuit until you are certain the circuit is
WARNING
Avoid Fire Hazard
Make sure electrical work is properly installed. Only qualified electricians should perform electrical work.
Electrical Supply
The customer has the responsibility of ensuring that the dishwasher electrical installation is in compliance with all national and local electrical codes and ordinances. The dishwasher is designed for an electrical supply of 120V, 60 Hz, AC, connected to a
Regardless of where the electrical supply cable enters the enclosure, position the cable 21” (533mm) from the enclosure’s left side, as shown in Figure 4. Extend the cable 30” (762mm) from the enclosure’s back, as shown in Figure 4.
Remove 3” - 4” (76mm - 102mm) of the cable’s outer casing, as shown in Figure 5, then remove 3/8” - 1/2” (10 - 13mm) of insulation from each wire, as shown in
Figure 5.